Analogues Plastic Components Screws


10000 Series Analogues
 
All analogues are made from stainless steel and are used during the laboratory procedure as a die in working model. They are threaded internally to accept abutments, and impression pins, as well as plastic laboratory components.
 
Implant Analogues: Used to replicate the internal taper & threads of the implant
 

S10001:
S10002:

ST10005:

ST10006:


A10001:
A10002:

A10003

3.25 mm Simpler Implant Analogue
4.0 mm Simpler Implant Analogue

5.0 mm Simpler Implant Analogue

6.0 mm Simpler Implant Analogue


3.0 mm Anchor Implant Analogue
4.0 mm Anchor Implant Analogue

RSA Analogue


Bar Post Analogue: Used to replicate the top of the Bar Post Abutment.

AS10004: Bar Post Analogue
 
O Ring Analogue: Replicates top of “O” ring connector. Used during lab procedure if
keeper is processed into denture base at same time denture is being processed.
 
AS10005: O Ring Analogue
top


20000 Series Plastic Components
 
All plastic components are designed to be used by the lab during the lost wax technique. All plastic components are only available in packages of 4.

Simpler UCLA Abutments: Plastic burnout copings usedby the lab to fit into the top of the Simpler implant for removable crowns & bridges. The coping is custom shaped & cast into metal. The porcelain or composite is bonded directly to the custom casting. The finished crown/bridge is attached to the implant with crown post screws.
 
S20031:
S20032:
3.25 mm Simpler UCLA Abutment
4.0 mm Simpler UCLA Abutment
 

Anchor UCLA Abutments: Plastic burnout copings usedby the lab to fit into the top of the Anchor implant for removable crowns & bridges. The coping is custom shaped & cast into metal. The porcelain or composite is bonded directly to the custom casting. The finished crown/bridge is attached to the implant with crown post screws.
 
A20001:
A20003:
Anchor 3.0 mm UCLA abutment
Anchor 4.0 mm UCLA abutment
 

Retaining Bar: Used during wax-up procedure of metal frameworks. Pear shaped cross section, shaped to accept the Hader and Doldar clips.

AS20005: Retaining Bar
 
Distal O Ring Coping: Used as a burnout coping to replicate an O Ring attachment at the distal of an abutment.
 
AS20006: Distal O Ring Coping
 

Straight O Ring Coping: Used as a burnout coping to replicate an O Ring attachment at the middle of a framework.
 
AS20007: Straight O Ring Coping
 
 
Plastic Bar Post Screw Housing: Used during the wax-up of the non “Passive Fit” framework as a burnout coping over the Bar Post Analogue when fabricating a metal framework for Bar Post Abutments.

AS20010: Plastic Bar Post Screw Housing

RSA Abutment Coping: Used as a burnout coping during the fabrication of Doldar bars over Anchor Retaining Screw Abutments
 
A20012: RSA Burnout Copings
 

Adjustable Castable Abutments: Used as a burnout coping during the
fabrication of cementable crown posts over Anchor implants
 
A20013:
3.0 mm ACAP (see image to right)
 
A20014:
4.0 mm ACAP
   

Bar Post Spacer: Used during the wax-up of the “Passive Fit” framework. Removed prior to casting to provide space for composite during intraoral light curing procedure.
 
AS16002: Bar Post Spacer

Bar Post Burnout Coping: Used during the wax-up of “Passive Fit” framework as part of the framework. Fits around the spacer.
 
AS16003: Bar Post Burnout Coping
top


21000 Series Screws
 
2mm Retaining Screw (Short): Used to retain Titanium Screw Housings to the Bar Posts Abutments.
 
AS21001: 2mm Retaining Screw (Short)

2mm Retaining Screw (Long): Used during pickup impression of bonded “Passive Fit” bar, during processing of dentures in lab procedures and to retain Fixed Detachable frameworks to Bar Post Abutments.
 
AS21003: 2mm Retaining Screw (Long)

Retaining Screw: Designed to hold removable crowns & UCLA abutments onto the top of the implant body. 

A21004:
A21005:
S17013:
S17014:


3.0 mm Anchor Retaining Screw
4.0 mm Anchor Retaining Screw
3.25 mm Simpler Crown Post Screw
4.0 mm Simpler Crown Post Screw

 

Crown Post & Bar Post Screw: Designed to hold SImpler removable crowns & UCLA abutments onto the top of the implant body.

S17013:   3.25 mm Simpler Crown Post Screw

S17014:   4.0 mm Simpler Crown Post Screw
AS9007:   Bar Post Impression Post Screw
.
.




©2005 Simpler Implants  |  Privacy Policy  |  Site Map  |  Contact Us